Difference between revisions of "LPC1768: RTC Programming"
m |
m |
||
| Line 48: | Line 48: | ||
|YEAR || Year value|| 0 to 4095 | |YEAR || Year value|| 0 to 4095 | ||
|} | |} | ||
| + | |||
| + | ===== Consolidated Time Registers ===== | ||
| + | |||
| + | The values of the Time Counters can optionally be read in a consolidated format which | ||
| + | allows the programmer to read all time counters with only three read operations | ||
=Steps for configuring RTC= | =Steps for configuring RTC= | ||
Revision as of 20:30, 4 June 2015
---
Contents
Objective
RTC Registers
CCR ( Clock Control Register )
| CCR | ||||||||
|---|---|---|---|---|---|---|---|---|
| 31:5 | 4 | 3:2 | 1 | 0 | ||||
| - | CCALEN | - | CTCRST | CLKEN | ||||
Bit 0 – CLKEN : Clock Enable
Bit 1 - CTCRST : CTC Reset
Bit 3:2
Bit 4 - CCALEN
Bit 31:5
Time Counter Register
| Time Counter Register | ||||||||
|---|---|---|---|---|---|---|---|---|
| Name | Description | Range | ||||||
| SEC | Seconds value | 0 to 59 | ||||||
| MIN | Minutes value | 0 to 59 | ||||||
| HOUR | Hours value | 0 to 23 | ||||||
| DOM | Day of Month value | 1 to 28,29,30 or 31 ( depending on the month and whether it is a leap year). | ||||||
| DOW | Day of Week value | 0 to 6 | ||||||
| DOY | Day of Year value | 1 to 365 (366 for Leap Year) | ||||||
| MONTH | Month value | 1 to 12 | ||||||
| YEAR | Year value | 0 to 4095 | ||||||
Consolidated Time Registers
The values of the Time Counters can optionally be read in a consolidated format which allows the programmer to read all time counters with only three read operations
Steps for configuring RTC
Code EXample
Example 1
Using Explore Embedded Liberaries